top of page
pioneerfibre-logo

Since 2002

2.PNE® SS-9054 Corrugated Steel Fiber for Concrete
pne-ss-9054-smooth-steel-fiber-for-concrete-reinforcement.

PNE® SS-9054

Corrugated Steel Fibers

Corrugated Steel Fibre for Concrete

Since 2002, we have specialized in concrete crack resistance, waterproofing, and anti-corrosion technologies.

Corrugated Steel Fiber Reinforcement for Concrete | PIONEER®

High-Tensile Wave-Shaped Steel Fibers for Crack Control, Flexural Toughness & Long-Term Durability

What Are PIONEER® Corrugated Steel Fibers?

PNE® SS-9054 Corrugated Steel Fibers are precision-engineered wave-shaped steel fibers designed for high-performance concrete, including SFRC (Steel Fiber Reinforced Concrete) and UHPC (Ultra-High-Performance Concrete).

Unlike straight or crimped fibers, corrugated steel fibers feature alternating wave deformation, providing:

  • Strong mechanical anchorage

  • ​Excellent pull-out resistance under heavy loads

  • ​Superior crack bridging capability

  • ​Improved bonding within the cement matrix

  • ​Enhanced toughness, ductility, and energy absorption

This geometry makes corrugated steel fibers a powerful, cost-effective replacement for welded wire mesh and rebar in industrial flooring, precast products, pavements, tunneling, mining, and UHPC applications.

Cuts Rebar Requirements

Reduces Crack Propagation

pne-ss-9054-corrugated-steel-fiber-reduces-crack-propagation.

Technical Specifications of Corrugated Steel Fibers

Explore the robust technical properties that ensure consistent performance in fibre reinforced concrete and shotcrete applications:

  • Material: High-tensile steel

  • Type: Corrugated (wave-shaped) steel fibre

  • Specific Gravity: 7.8 g/cm³

  • Length: 30 mm, 50 mm (custom sizes available)

  • Diameter: 0.9 mm

  • Aspect Ratio: 40–60

  • Tensile Strength: 650–1000 MPa

  • Modulus of Elasticity: 200 GPa

  • Color: Metallic gray

Applicable standards and test methods

PIONEER® steel fibers are developed with reference to internationally recognized standards for steel fiber products and fiber-reinforced concrete. Applicable standards and documentation depend on the product grade, intended application, project requirements, and destination market.​

  • ASTM A820/A820M — Standard Specification for Steel Fibers for Fiber-Reinforced Concrete 

  • ASTM C1116/C1116M — Standard Specification for Fiber-Reinforced Concrete 

  • EN 14889-1:2006 — Fibres for Concrete — Part 1: Steel Fibres — Definitions, Specifications and Conformity 

These standards provide technical references for steel fiber selection and use in precast concrete, industrial floors, shotcrete, and other fiber-reinforced concrete applications. Product suitability should be confirmed according to the project design, required performance, and applicable local regulations.

Key Benefits of Corrugated Steel Fibers

  • Superior Mechanical Anchorage

Wave-shaped geometry increases bonding and pull-out resistance dramatically.

  • Enhanced Flexural Strength & Toughness

Ideal for industrial floors, heavy pavements, precast concrete, and UHPC systems.

  • Effective Crack Control

Reduces plastic and drying shrinkage cracking in early-stage concrete.

  • Replacement for Mesh & Rebar

Improves construction efficiency while reducing material and labor costs.

  • Improved Impact, Abrasion & Fatigue Resistance

Performs exceptionally well in heavy-load and dynamic environments.

  • Reliable Load Transfer & Long-Term Durability

Ensures consistent performance in high-stress applications.

pne-ss-9054-lowering-labor-and-material-costs-in-construction.

Lowering labor and material costs

pne-ss-9054-steel-fiber-reinforcement-mixing-with-concrete.

Steel fiber reinforcement

Applications of Corrugated Steel Fiber Reinforcement

PIONEER® corrugated steel fibers are ideal for:

Industrial & Structural Concrete

  • Industrial floors, warehouse slabs

  • Pavements, port slabs, airport aprons

  • Composite metal decks, overlays

Precast & UHPC Products

  • Precast panels, thin-wall elements

  • UHPC facades and architectural components

  • Tunnel segments, pipes, beams

Shotcrete

  • Tunnel linings

  • Slope stabilization

  • Mining shotcrete and dry-mix applications

hong-kong-zhuhai-macao-bridge-with-polypropylene-macro-fiber-shotcrete.

Hong Kong-Zhuhai-Macao Bridge

da-nang-pier-vietnam-steel-fiber-reinforced-concrete-marine-structure.

Da Nang Pier, Vietnam

hangzhou-olympic-center-polypropylene-microfiber-for-crack-control.

Hangzhou Olympic Center

Usage Guidelines for Optimal Performance

Ensure the best results with PIONEER® corrugated steel fibres in fibre reinforced concrete and shotcrete:

  1. Dosage: 15–45 kg/m³, adjusted based on design requirements.

  2. Mixing: Add after aggregates, before water; mix for 3–5 minutes for even fibre dispersion.

  3. Placement: Compatible with standard pumping, casting, vibrating, and screeding methods.

  4. Finishing: Conventional tools can be used; minor fibre visibility may occur without affecting performance.

Custom Steel Fibre Solutions for Concrete Reinforcement

We offer customizable reinforcement solutions for SFRC & UHPC:

Lengths: Standard and custom lengths available to suit project needs.

Packaging: 

  • Water-soluble paper bags (5 kg, 10 kg) for direct addition into the mixer.

  • Cardboard cartons for organized on-site handling.

  • Bulk packaging options available based on project logistics.

pioneerfibre-engineer-on-site-technical-support.

Have Any Questions?
Get in Touch with Us Now!

Contact Our Sales & Technical Team

For product inquiries, quotations, technical support, or distribution opportunities,

contact our team directly.

Email

Sales & Business: Sales@pioneerfibre.com
Technical Support: Support@pioneerfibre.com

WhatsApp

Sales Manager: +1 (406) 717-9829
Technical Director: +1 (929) 569-9992

Get a Quick Quote or Product Recommendation

​Tell us about your application, and our team will help you find the right product and solution.Select your application below for a faster response.

Privacy Assurance: We respect your privacy and will never share your information. 

Why Choose Us?

Proven Expertise & Greater Savings

24 years of focus

on fiber reinforcement solutions.

5,000 tons yearly

from advanced manufacturing.

20+ countries served

with global product distribution.

1,000 projects proven

 in diverse applications worldwide.

Why Choose PIONEER® Technologies

Product-Specific Documentation

Request current technical data sheets, available test reports and applicable conformity documents for the selected steel fiber.

Application-Based Selection

Select steel fibers according to the concrete application, production process and specified performance requirements.

Steel Fiber Options

Compare available fiber geometries, dimensions and supply formats for industrial floors, precast concrete, shotcrete and other selected applications.

Technical Support

Get support with product selection, dosage evaluation and mixing procedures. Reinforcement design requires project-specific engineering review and supporting performance data.

PIONEER® factory aerial view.

26,500m² production base

Spinning of concrete reinforcing fibers production process.

Advanced fiber dispersibility

Tensile strength of concrete reinforcement fiber production process.

Exceptional tensile strength

FAQ

  • PNE® SS-9054 is a corrugated steel fiber for fiber-reinforced concrete. It uses an alternating wave-shaped profile that distinguishes it from crimped, hooked-end and straight steel fiber geometries.

  • The corrugated profile creates repeated mechanical-interaction points between the steel fiber and the surrounding concrete matrix. Fibers crossing a crack plane can participate in crack bridging and post-crack load transfer.

  • Final dosage should follow the current PNE® SS-9054 TDS and should be selected according to the concrete application, required performance, applicable test method and project design.

  • It may be considered in selected applications where project design, performance testing and applicable approvals support reduction or substitution of conventional reinforcement. It is not a universal replacement for mesh or rebar.

  • It can be evaluated for selected pumped-concrete and shotcrete applications. Suitability should be confirmed according to fiber dimensions, dosage, concrete mix, batching sequence, pumping or placement requirements and the performance required by the project.

bottom of page